Control water presure, and extend pump life by reducing water surging.
FeaturesThese fit in line, between the water pump and outlet taps. While non-essential for the system to work, they reduce pulsation levels. They should be installed with the fittings at the base.These need to be mounted vertically - the air in the chamber is compressed - if it is not vertical or near vertical less air will reside in the chamber (it will just escape down the pipe) and this will limit its effect.
he difference between just the pulsation dampener and the accumulaor/pulsation dampener is in the way they are made, therefore operate. The pulsation dampener just relies on the water compressing the standard air pressure within the unit - without a diaphragm. The accumulators have the air inside under pressure in the start up stage, so in effect this gives a longer time (more water flow) between stop and start of pump for the same sized unit.Shurflo pulsation dampener
SpecificationsDimensions: 275mm x 103mm (includes T piece)
Total Volume: 710 ml
Maximum PSI: 125 PSI [8.8 Bar]
Connections: 12.5mm barb x 2
|